Indoor/Outdoor Fiber Optic Drop cable, 1 Fiber G657 A2 0.9mm tight buffer. Breaking load Max 2000N. Suitable for installation under overhead power lines ≤11kV, vertical clearance ≥1.8m.

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.
Features and Benefits
Fire retardant Outside plant LSZH jacket grade, suitable for drop / aerial installations of up to 68 m. Can be routed indoor.

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | North America
Portfolio CommScope®
Product Type Fiber indoor/outdoor cable

General Specifications

Cable Type Drop | Tight buffer
Construction Type All Dielectric | Non-armored
Subunit Type Gel-free
Jacket Color Black
Jacket Marking Meters
Jacket Marking Method Inkjet
Jacket Marking Text COMMSCOPE GB OPTICAL CABLE 810010113/DB 1x G657A2 SM LSZH [DOM] [SERIAL NUMBER] [METER MARK]
Subunit, quantity 1
Fibers per Subunit, quantity 1
Total Fiber Count 1

Dimensions

Buffer Tube/Subunit Diameter 0.9 mm | 0.035 in
Diameter Over Jacket 3 mm | 0.118 in

Representative Image

Click on image to enlarge.

Material Specifications

Jacket Material Low Smoke Zero Halogen (LSZH)

Mechanical Specifications

Minimum Bend Radius, loaded 30 mm | 1.181 in
Tensile Load, long term, maximum 300 N | 67.443 lbf
Tensile Load, short term, maximum 620 N | 139.382 lbf
Compression 20 N/mm | 114.203 lb/in
Compression Test Method IEC 60794-1 E3
Impact 2 N-m | 17.701 in lb
Impact Test Method IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method IEC 60794-1 E1
Twist 10 cycles
Twist Test Method IEC 60794-1 E7

Optical Specifications

Fiber Type G.657.A2, TeraSPEED®

Environmental Specifications

Installation temperature -10 °C to +60 °C (+14 °F to +140 °F)
Operating Temperature -30 °C to +65 °C (-22 °F to +149 °F)
Storage Temperature -30 °C to +60 °C (-22 °F to +140 °F)
Cable Qualification Standards IEC 60794-1-2
EN50575 CPR Cable EuroClass Fire Performance Dca
EN50575 CPR Cable EuroClass Smoke Rating s1a
EN50575 CPR Cable EuroClass Droplets Rating d0
EN50575 CPR Cable EuroClass Acidity Rating a1
Environmental Space Aerial | Drop | Ducted | Indoor/Outdoor
Flame Test Listing EN 50399
Flame Test Method IEC 60332-1-2 | IEC 60754-2 | IEC 61034-2
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penetration Test Method IEC 60794-1 F5

Environmental Test Specifications

Temperature Cycle -30 °C to +60 °C (-22 °F to +140 °F)
Temperature Cycle Test Method IEC 60794-1-22 F1

Packaging and Weights

Cable weight 8.7 kg/km | 5.846 lb/kft

Regulatory Compliance/Certifications

Agency Classification
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | North America
Portfolio CommScope®
Product Type Fiber indoor/outdoor cable

General Specifications

Cable Type Drop | Tight buffer
Construction Type All Dielectric | Non-armored
Subunit Type Gel-free
Jacket Color Black
Jacket Marking Meters
Jacket Marking Method Inkjet
Jacket Marking Text COMMSCOPE GB OPTICAL CABLE 810010113/DB 1x G657A2 SM LSZH [DOM] [SERIAL NUMBER] [METER MARK]
Subunit, quantity 1
Fibers per Subunit, quantity 1
Total Fiber Count 1

Dimensions

Buffer Tube/Subunit Diameter 0.9 mm | 0.035 in
Diameter Over Jacket 3 mm | 0.118 in

Material Specifications

Jacket Material Low Smoke Zero Halogen (LSZH)

Mechanical Specifications

Minimum Bend Radius, loaded 30 mm | 1.181 in
Tensile Load, long term, maximum 300 N | 67.443 lbf
Tensile Load, short term, maximum 620 N | 139.382 lbf
Compression 20 N/mm | 114.203 lb/in
Compression Test Method IEC 60794-1 E3
Impact 2 N-m | 17.701 in lb
Impact Test Method IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method IEC 60794-1 E1
Twist 10 cycles
Twist Test Method IEC 60794-1 E7

Optical Specifications

Fiber Type G.657.A2, TeraSPEED®

Environmental Specifications

Installation temperature -10 °C to +60 °C (+14 °F to +140 °F)
Operating Temperature -30 °C to +65 °C (-22 °F to +149 °F)
Storage Temperature -30 °C to +60 °C (-22 °F to +140 °F)
Cable Qualification Standards IEC 60794-1-2
EN50575 CPR Cable EuroClass Fire Performance Dca
EN50575 CPR Cable EuroClass Smoke Rating s1a
EN50575 CPR Cable EuroClass Droplets Rating d0
EN50575 CPR Cable EuroClass Acidity Rating a1
Environmental Space Aerial | Drop | Ducted | Indoor/Outdoor
Flame Test Listing EN 50399
Flame Test Method IEC 60332-1-2 | IEC 60754-2 | IEC 61034-2
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penetration Test Method IEC 60794-1 F5

Environmental Test Specifications

Temperature Cycle -30 °C to +60 °C (-22 °F to +140 °F)
Temperature Cycle Test Method IEC 60794-1-22 F1

Packaging and Weights

Cable weight 8.7 kg/km | 5.846 lb/kft
Click on image to enlarge.

Regulatory Compliance/Certifications

Agency Classification
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

Declaration of Performance

Product Specification

Declaration of Performance

Product Specification