BTTF-Q | BTTF*-*Q F-Port Power Extracting Taps
- Available in:
- Asia
- Australia/New Zealand
- EMEA
- Latin America
- North America
1.2 GHz Power Extracting Taps
Get Connected to the Access Technologies Resource Center
Find manuals, quick guides, data sheets, videos and much more!
Features and Benefits
The ARRIS 1.2 GHz power extracting taps are capable of delivering video, telephony, and data over the broadband hybrid fiber coax system. These taps have all of the same features and performance as our standard Q‐series FFT taps, including 12 ampere power passing and surge resiliency, but with the additional feature of power extracting for Cable Wi‐Fi® applications.
The BTTF*‐*Q taps extract power from the cable feeder and deliver it to the Cable Wi‐Fi Access Point via the F‐Port (Port 1, jumper selectable). RF signals are distributed through the F‐ports to the coaxial drop, as well.
The BTTF*‐*Q taps extract power from the cable feeder and deliver it to the Cable Wi‐Fi Access Point via the F‐Port (Port 1, jumper selectable). RF signals are distributed through the F‐ports to the coaxial drop, as well.
- Support expanded bandwidth up to 1218 MHz
- Enable Cable Wi-Fi Access Point powering via the F-port
- Improve network performance with signal conditioning plug-ins
- High quality RF connection with auto-seize F-connectors
- Maintain existing install base with compatibility back to “F” series FFT housings
- High level of network resilience with 6kV surge resistance
- Maintain RF and AC continuity with integrated bypass capability
Specifications
Product Classification
Regional Availability | Asia | Australia/New Zealand | EMEA | Latin America | North America |
Product Type | RF tap |
Electrical Specifications
Return Loss at Frequency Band, tap | 16 dB @ 5–9 MHz, 17 dB @ 10–749 MHz, 17 dB @ 750–1000 MHz, 16 dB @ 1001–1218 MHz |
Hum Modulation at Operating Frequency | 60 dB minimum @ 5–10 MHz, 65 dB minimum @ 11–550MHz, 60 dB minimum @ 551–1000MHz, 55 dB minimum @ 1001–1218MHz |
Isolation at Frequency Band, tap to tap | 20 dB @ 5–9 MHz, 25 dB @ 10–85 MHz, 24 dB @ 86–300 MHz, 23 dB @ 301–749 MHz, 20 dB @ 750–1218 MHz |
Power Passing at 60/90V, maximum | 12 A |
Surge Protection, F port | 6 kV Combination Wave |
Surge Protection, input/output ports | 6 kV Combination Wave |
Environmental Specifications
Operating Temperature | -40 °C to +60 °C (-40 °F to +140 °F) |
Standards Compliance | Edition 2.0 2016‐01 | IEC 60950‐22 |
Product Classification
Regional Availability | Asia | Australia/New Zealand | EMEA | Latin America | North America |
Product Type | RF tap |
Electrical Specifications
Return Loss at Frequency Band, tap | 16 dB @ 5–9 MHz, 17 dB @ 10–749 MHz, 17 dB @ 750–1000 MHz, 16 dB @ 1001–1218 MHz |
Hum Modulation at Operating Frequency | 60 dB minimum @ 5–10 MHz, 65 dB minimum @ 11–550MHz, 60 dB minimum @ 551–1000MHz, 55 dB minimum @ 1001–1218MHz |
Isolation at Frequency Band, tap to tap | 20 dB @ 5–9 MHz, 25 dB @ 10–85 MHz, 24 dB @ 86–300 MHz, 23 dB @ 301–749 MHz, 20 dB @ 750–1218 MHz |
Power Passing at 60/90V, maximum | 12 A |
Surge Protection, F port | 6 kV Combination Wave |
Surge Protection, input/output ports | 6 kV Combination Wave |
Environmental Specifications
Operating Temperature | -40 °C to +60 °C (-40 °F to +140 °F) |
Standards Compliance | Edition 2.0 2016‐01 | IEC 60950‐22 |
Documentation & Downloads
Product Specification
Warranty
Product Specification
Warranty
Other Ways to Browse